Vista de pagina 22
23
D
ATA
S
ETTING
85%
15%
GAIN1
setting
GAIN2
setting
70%
30%
AVCS side
Normal side
70% 40%
[Setting Example]
Adjust the gyro gain at the Gyro Sense Mixing setup screen at each condi-
tion.
The following shows a setting example in the CMT mode.
Use the following values as the sensitivity setting standard:
CH5 switch
Actual gain:
Hovering Flight
The GY611 sensitivity is 0% at 50%. When set over 50%, the GY611 oper
-
ates in the AVCS mode and when set under 50%, the GY611 operates in the
Normal mode. When setting is changed 1%, the gyro sensitivity is changed
2%.
GYRO SENSE
01 . MODEL-01. NORML HEL PCM 0: 23: 17
DUAL : MODE
: GAIN 1
: GAIN 2
0 20 40 60 80 100
END
85 %
15 %
Select the Dual Mode (DUO).
Sensitivity rate: Choose the GAIN1 or
GAIN2 by the CH5 switch.